AV-HS6000 Series Composition | ||
Model no | ||
Mainframe | Single Power Supply Model | AV-HS60U1P/AV-HS60U1E |
Mainframe | Redundant Power Supply Model | AV-HS60U2P/AV-HS60U2E |
Control Panel | Single Power Supply Model | AV-HS60C1P/AV-HS60C1E |
Control Panel | Redundant Power Supply Model | AV-HS60C2P/AV-HS60C2E |
Menu Panel | AV-HS60C3G | |
Storage Module | AV-HS60D1G | |
Chroma Key Software | AV-SFU60G | |
※備註 本表僅供參考,若有任何差異將以實機功能為準。 |
Mainframe AV-HS60U1P/E,AV-HS60U2P/E | ||
Power Supply | AC100 V to 240 V, 50 Hz/60 Hz (AV-HS60U2 supports redundant power supply) |
|
Power Consumption | 110W | |
Ambient Operating Temperature | 0°C to 40°C (32°F to 104°F) | |
Operating Ambient Humidity | 10% to 90% (no condensation) | |
Storage Temperature | 0°C to 40°C (32°F to 104°F) | |
Storage Humidity | 10% to 90% (no condensation) | |
Weight | AV-HS60U1: Approx. 12.6 kg(27.8 lbs.)(excluding accessories) AV-HS60U2: Approx. 13.5 kg(29.7 lbs.)(excluding accessories) |
|
Dimensions(WxHxD) | 482 mm×132 mm×418 mm (18-31/32 inches×5-3/16 inches×16-15/32 inches)(excluding protrusions) |
|
Video Terminal | ||
SDI IN 1 to SDI IN 32 Terminals | 32 lines • Connectors: BNCx32 • SDI IN 27, SDI IN 28, SDI IN 31, SDI IN 32 terminals are equipped with up-converters. • SDI IN 25 to SDI IN 32 terminals are equipped with color correctors.*1 |
|
HD-SDI | SMPTE292M (BTA S-004) standard compliant • 0.8 V [p-p]±10% (75 Ω) • Automatic equalizer more than 100 m(328 ft) (when 1.5 Gbps/5C-FB cable is used) |
|
SD-SDI | SMPTE259M standard compliant • 0.8 V [p-p]±10% (75 Ω) • Automatic equalizer 200 m (656 ft) (when 5C-2V cable is used) |
|
DVI-D IN 1 to DVI-D IN 2 Terminals | 2 lines Digital RGB:XGA (1024×768), WXGA (1280×768), SXGA (1280×1024), WSXGA+ (1680×1050),UXGA (1600×1200), WUXGA (1920×1200) Vertical frequency: 60 Hz Video format inputs: 1080/59.94p, 1080/50p, 1080/59.94i, 1080/50i, 720/59.94p, 720/50p • Connectors: DVI-D×2 • The terminals do not support HDCP. • The DVI-I connector cable cannot be used. • For the DVI-D connector cable, use a cable with a length of up to 5 m.(16.4 ft) |
|
SDI OUT 1 to SDI OUT 16 Terminals | 16 lines (2 distributed outputs per line) • Connectors: BNCx32 • ME1PGM, ME1PVW, ME1CLN, ME1KEYPVW, ME2PGM, ME2PVW, ME2CLN, ME2KEYPVW, DSKPGM1, DSKPGM2, DSKPVW1, DSKPVW2, DSK1CLN, DSK2CLN, DSK3CLN, DSK4CLN, SEL KEYPVW, MV1 to MV4, and AUX1 to AUX16 can be assigned. |
|
HD-SDI | SMPTE292M (BTA S-004) standard compliant • Output level: 0.8 V [p-p]±10% |
|
SD-SDI | SMPTE259M standard compliant • Output level: 0.8 V [p-p]±10% |
|
Signal Formats | SD | 480/59.94i, 576/50i |
HD | 1080/59.94i, 1080/50i, 720/59.94p*1, 720/50p*1, 1080/24PsF*1, 1080/23.98PsF*1 1080/25PsF*1 |
|
Signal Processing | Y:PB:PR | 4:2:2 10 bit |
R:G:B | 4:4:4 8 bit | |
ME Number | 2 ME | |
Synchronous Terminal | ||
REF Terminal | • Connectors: BNC • Same field frequencies as those of the system formats supported In Genlock mode: Black burst or Tri-level Sync input signals (with loop-through) • If the loop-through output is not used, provide a 75 Ω termination. • In the 1080/24PsF and 1080/23.98PsF formats, only Genlock mode supported • In the 1080/23.98PsF format, black burst signals with 10 Field ID (SMPTE318M standard compliant) or Tri-level Sync signals supported • In the 1080/24PsF format, Tri-level Sync signals supported In internal sync mode: Black burst output signal ×2 |
|
LTC IN Terminal | This is the LTC (linear time code) input terminal. • Connectors: BNC • Impedance: 1 kΩ • Level: 1 to 2 V [p-p] |
|
Video Delay Time | 1 line (H) | When the frame synchronizer is set to " Off "and the up-converter is set to " Off " |
1 frame (F) | When the frame synchronizer is set to " On " , or the up-converter is set to '" On " | |
• When the signals have passed through PinP, DVE, MultiView, down-converter, or DVI-IN, a maximum delay of 1 frame is applied in each case. |
||
Control Terminal | ||
LAN Terminal | Compatible with 100Base-TX and AUTO-MDIX (For IP control) • Connection cable: LAN cable (CAT5E), max. 100 m (328 ft), STP (Shielded Twisted Pair) cable recommended • Connector: RJ-45 |
|
PANEL Terminal | Compatible with 100Base-TX and AUTO-MDIX (For Control Panel AV-HS60C1/AV-HS60C2 connection) • Connection cable (supplied with AV-HS60C1/AV-HS60C2): LAN cable (CAT5E), straight cable, STP (Shielded Twisted Pair), 10 m (32.8 ft) • Connector: RJ-45 |
|
COM1(M)/COM2(M)/ COM3(M)Terminals |
RS-422 Control Terminal For master connection for controlling external devices • Connector: D-sub 9-pin (female) x 3, inch screw |
|
COM4(M/S) Terminal | RS-422 Control Terminal For master/slave connection for controlling external devices • Connector: D-sub 9-pin (female), inch screw • Switchable between master connection and slave connection via menu |
|
GPI IN Terminal | GPI IN: 18 inputs, general-purpose, photocoupler sensing ALARM OUT: 1 output, open collector output (negative logic) • Connector: D-sub 25-pin (female), inch screw |
|
GPI OUT1/GPI OUT 2 terminal |
GPI OUT: 48 outputs, selected from general purpose, tally Open collector output • Connector: D-sub 25-pin (female) x 2, inch screw |
|
※備註 本表僅供參考,若有任何差異將以實機功能為準。 |
Control Panel AV-HS60C1P/E,AV-HS60C2P/E | |
Power Supply | AC100 V to 240 V, 50 Hz/60 Hz (AV-HS60C2 supports redundant power supply) |
Power Consumption | 40 W |
Operating Ambient Temperature |
0°C to 40°C (32°F to 104°F) |
Operating Ambient Humidity |
10% to 90% (no condensation) |
Storage Temperature | 0°C to 40°C (32°F to 104°F) |
Storage Humidity | 10% to 90% (no condensation) |
Weight | AV-HS60C1: Approx. 13.0 kg(28.6 lbs.)(excluding accessories) AV-HS60C2: Approx. 13.9 kg(30.6 lbs.)(excluding accessories) |
Dimensions(WxHxD) | 980 mm×153.4 mm×267 mm (38-19/32 inches×6-1/32 inches×10-1/2 inches) (excluding protrusions) |
Control Terminal | |
Mainframe Terminal | Compatible with 100Base-TX and AUTO-MDIX (For Mainframe AV-HS60U1/AV-HS60U2 connection) Connection cable (supplied with AV-HS60C1/AV-HS60C2): LAN cable (CAT5E), Straight cable, STP (Shielded Twisted Pair), 10 m (32.8 ft) • Connector: RJ-45 When connected to the <LAN> terminal, no video will be displayed on the Menu Panel AV-HS60C3G. |
MENU PANEL Terminal | Used only for the Menu Panel AV-HS60C3G • Connector: DVI-D • Because an independent signal format is used,cannot be displayed on a DVI-D monitor. • Cannot be used concurrently with a DVI-D monitor (computer) connected to the <DVI-D> terminal. Select with the display selector switch |
DVI-D Terminal | Used for displaying menus to the DVI monitor (computer) • Connector: DVI-D • Monitor resolution: 1366×768 compatible monitor • Cannot be used concurrently with the <MENU PANEL> terminal. Select with the display selector switch. |
USB Terminal | For DVI monitor (computer) menu operation • Connector: USB (type A, female) • Cannot be used for the Menu Panel AV-HS60C3G. |
Display Selector Switch | Switch for selecting <MENU PANEL> terminal or <DVI-D> terminal |
COM1(M) Terminal | RS-422 Control Terminal For master connection for controlling external devices • Connector: D-sub 9-pin (female), inch screw |
COM2(RS-232) Terminal | RS-232 Control Terminal For master/slave connection for controlling external devices • Connector: D-sub 9-pin (female), inch screw • Switchable between master connection and slave connection via menu |
GPI I/O Termina | GPI IN: 8 inputs, general-purpose, photocoupler sensing ALARM OUT: 1 output, open collector output (negative logic) GPI OUT: 10 outputs, selected from general purpose, tally Open collector output • Connector: D-sub 25-pin (female), inch screw |
ME Number | 2ME |
Menu Panel AV-HS60C3G | |
Power Supply | DC12 V/0.54 A (Supplied from AV-HS60C1/AV-HS60C2 using the supplied cable) |
Power Consumption 6 | 6.48 W |
Operating Ambient Temperature |
0°C to 40°C (32°F to 104°F) |
Operating Ambient Humidity |
10% to 90% (no condensation) |
Storage Temperature | 0°C to 40°C (32°F to 104°F) |
Storage Humidity | 10% to 90% (no condensation) |
Weight | Approx. 1.7 kg (3.7 lbs.) (excluding accessories) |
Dimensions(WxHxD) | 290 mm×177 mm×46.1 mm (11-13/32 inches×6-31/32 inches×1-13/16 inches) (excluding protrusions) 4RU |
Control Terminal | |
Control Panel Terminal | Used only for the Control Panel AV-HS60C1/AV-HS60C2 • Connectors: DVI-D • Because an independent signal format is used,DVI-D source cannot be displayed. • Cannot be used concurrently with a DVI-D monitor connected to the <DVI-D> terminal of the Control Panel AV-HS60C1/ AV-HS60C2. Set the display selector switch of the Control Panel AV-HS60C1/AV- HS60C2 to the <MENU PANEL> terminal side. |
Accessories | • Connecting cable (with ferrite core) for the Control Panel AV-HS60C1/AV- HS60C2 : 1cable • Bracket for mounting the Control Panel AV-HS60C1/AV-HS60C2 • Screws for the bracket for mounting the Control Panel AV-HS60C1/AV- HS60C2 : 6 screws |
Storage Module AV-HS60D1G | |
Weight | Approx. 7.0 g (0.3 ozs.) |
Dimensions(WxHxD) | 29.85 mm×4.0 mm×50.8 mm (1-3/16 inches×5/32 inches×2 inches) |
Accessories | • AV-HS60D1 Installation Guide |
Due to device characteristics, the storage module AV-HS60D1G is subject to data damage and overwriting restrictions. Backup of important data is recommended. |
|
※備註 本表僅供參考,若有任何差異將以實機功能為準。 |